Settings?
Alarm Call?
Settings / Alarm Call?
|
Alarm Number 1: |
Entry of the first phone number for voice alarms. |
|
Alarm Type 1: |
Selection of data protocol for this number, or selection of alarm call type (see “call routing”). |
|
Alarm Number 2: |
Entry of the second phone number for voice alarms. |
|
Alarm Type 2: |
See Alarm Type 1. |
|
Alarm Number 3: |
Entry of the third phone number for voice alarms. |
|
Alarm Type 3: |
See Alarm Type 1. |
|
Alarm Number 4: |
Entry of the fourth phone number for voice alarms. |
|
Alarm Type 4: |
See Alarm Type 1. |
|
End Of Alarm: |
Behaviour of the NRT when the voice connection ends after a lift alarm. |
|
Alarm Sound: |
Enables, disables and adjusts the alarm sound settings while the alarm button is pressed. |
Timer Call ?
Settings / Timer Call?
|
Timer Number: |
Phone number for test calls according to EN81-28. |
|
Timer Type: |
Selection of data protocol, or selection of timer call type. |
|
Timer Time: |
Sets the time for the timer call. |
|
Timer Call: |
Activation of timer call and configuration of the desired intervals. |
|
Timer Failure: |
Display of unsuccessful timer calls as an alternating blinking illuminated pictogram. |
Alert Message?
Settings / Alert Message?
|
Alert Number 1: |
Entry of the first phone number for Alert Messages. |
|
Alert Type 1: |
Selection of data protocol, or selection of alert type for number 1. |
|
Alert Number 2: |
Entry of the second phone number for Alert Messages. |
|
Alert Type 2: |
Selection of data protocol, or selection of alert type for number 2. |
|
Alert Audiofail: |
Activation and selection of the transmission options for the audio test. |
|
Alert Alarmfail: |
Activation and selection of the transmission options for the alarm button test. |
|
Alert Powerfail: |
Activation and selection of the transmission options for the power supply status. |
|
Alert Battery: |
Activation and selection of the transmission options for the integrated battery status. |
Voice Units?
Settings? / Voice Units?
ALARM 1 ?
Settings? / Voice Units? / ALARM 1
|
Alarm 1 Type: |
Selection of installation location of voice unit 1. |
|
Alarm 1 Latency: |
Selection of the activation duration of the alarm button for voice unit 1. |
|
Alarm 1 Filter: |
Enables or disables the alarm filter for this voice unit. |
|
Alarm 1 LSP: |
Selection of the speaker activated by alarm button 1. |
|
Alarm 1 MIC: |
Selection of the microphone activated by alarm button 1. |
|
Alarm 1 Audio: |
Enables the audio test for the selected speaker/microphone combination. |
|
Alarm 1 Test: |
Enables the test of alarm button 1. |
|
Alarm 1 Mode: |
Enables or disables the voice unit. |
ALARM 2 ?
Settings? / Voice Units? / ALARM 2
|
Alarm 2 Type: |
Selection of installation location of voice unit 2. |
|
Alarm 2 Latency: |
Selection of the activation duration of the alarm button for voice unit 2. |
|
Alarm 2 Filter: |
Enables or disables the alarm filter for this voice unit. |
|
Alarm 2 LSP: |
Selection of the speaker activated by alarm button 2. |
|
Alarm 2 MIC: |
Selection of the microphone activated by alarm button 2. |
|
Alarm 2 Audio: |
Enables the audio test for the selected speaker/microphone combination. |
|
Alarm 2 Test: |
Enables the test of alarm button 2. |
|
Alarm 2 Mode: |
Enables or disables the voice unit. |
ALARM 3 ?
Settings? / Voice Units? / ALARM 3
|
Alarm 3 Type: |
Selection of installation location of voice unit 3. |
|
Alarm 3 Latency: |
Selection of the activation duration of the alarm button for voice unit 3. |
|
Alarm 3 Filter: |
Enables or disables the alarm filter for this voice unit. |
|
Alarm 3 LSP: |
Selection of the speaker activated by alarm button 3. |
|
Alarm 3 MIC: |
Selection of the microphone activated by alarm button 3. |
|
Alarm 3 Audio: |
Enables the audio test for the selected speaker/microphone combination. |
|
Alarm 3 Test: |
Enables the test of alarm button 3. |
|
Alarm 3 Mode: |
Enables or disables the voice unit. |
AUDIO ?
Settings? / Voice Units? / AUDIO
|
.LSP 1 Voice Gain: |
Speaker volume of voice unit 1 during voice connection. |
|
LSP 1 Audio Gain: |
Speaker volume of voice unit 1 for signal tones, voice messages, etc. |
|
LSP 2 Voice Gain: |
Speaker volume of voice unit 2 during voice connection. |
|
LSP 2 Audio Gain: |
Speaker volume of voice unit 2 for signal tones, voice messages, etc. |
|
LSP 3 Voice Gain: |
Speaker volume of voice unit 3 during voice connection. |
|
LSP 3 Audio Gain: |
Speaker volume of voice unit 3 for signal tones, voice messages, etc. |
|
MIC 1 Voice Gain: |
Microphone sensitivity of voice unit 1. |
|
MIC 2 Voice Gain: |
Microphone sensitivity of voice unit 2. |
|
MIC 3 Voice Gain: |
Microphone sensitivity of voice unit 3. |
Inputs?
Settings? / Inputs?
|
Terminal INPUT: |
Selection of operating mode for the input. |
Outputs?
Settings? / Outputs?
|
Terminal OUTPUT: |
Selection of the operating mode for the output. |
|
Fault Filter: |
If the OUTPUT terminal is used as a general fault output (STOERUNG NO or STOERUNG NC), individual faults can be filtered out so that output does not react to them. |
|
Output PICTO: |
The outputs for the illuminated pictograms can be switched manually here for test purposes. |
Connectivity ?
Settings? / Connectivity?
|
Line Type: |
Selection of line connection type (PSTN or cellular gateway). |
|
Line Dial Mode: |
Selection of the dialling mode. |
|
Call Blocker: |
Activation / deactivation of call protection. |
|
Dial Retries: |
Configuration of the possible dialling attempts for all phone numbers. |
|
Ext Line Access: |
Configuration of the external line access prefix. |
|
Ext Access Code: |
Configuration of the access code for external line. |
|
Talk Limit: |
Setting of the maximum possible talk time. |
|
Filter Bypass: |
Setting the duration for which the alarm button must be pressed to trigger a lift alarm if the alarm filter is active. |
|
Privacy Tone: |
Activation / deactivation of the privacy tone. |
WEM Modul?
Settings? / WEM Modul?
|
WEM Modul Mode: |
Display of the activation status of the WEM module: WEM SERVICE ONLY:
WEM SERVICE+VNS
|
|
WEM Power: |
Setting the transmission power for the wireless (WiFi) signal.
|
|
WEM Servicecode: |
Entry of the WiFi key for the service mode.
|
|
WEM VNS SSID: |
Configuration of the network name for the wireless (WiFi) network established during a lift alarm. The following values can be selected:
If only a single lift installation is present, the factory setting “emergency_call” can be retained.
Please note that the supplied sticker is valid only for the WiFi name “emergency_call”. Stickers for the other network names are available from Telegärtner Elektronik GmbH on request. |
System?
Settings? / System?
|
Device Number: |
Setting the device number when the lift alarm is routed to an alarm receiving centre using the Telegärtner protocol. |
|
Access PIN Code: |
Changing the access PIN code:
|
|
P100 ID-Code: |
Setting the P100 ID when the lift alarm is routed to an alarm receiving centre using the P100 protocol. |
|
System Time: |
Set time. |
|
System Date: |
Set date. |
|
System-Bus? |
|
|
DTMF Twist: |
This value is for information only and may only be changed after consultation with Telegärtner Elektronik GmbH. |
|
Impedance PSTN: |
Sets the impedance for PSTN when “Line type = PSTN” is selected under “Connectivity”. |
|
Impedance Cell: |
Sets the impedance for “cellular” when “Line type = cell” is selected under “Connectivity”. |
|
Language: |
Sets the language. |
System-Bus?
Settings? / System? / System-Bus
|
Bus Mode: |
Defines the operating mode for the system bus. Single device: Default setting when only one alarm device is connected. DISABLED: The bus operation is disabled; no IP configuration or multi-device operation is possible. AUTO ADRESS: The alarm device detects its bus address automatically.
|
|
Bus Adress: |
Anzeige/Auswahl der Bus-Adresse. |
|
Bus Speed: |
The bus speed can be set between 300 and 4800 bit/s.
Note: Bus speed must be configured identically at the cellular gateways! |
Factory Reset?
Factory Reset?
|
Are you sure? |