Breadcrumbs

Technical data

General


Power supply

12 - 24 V DC
max. 500 mW @ 12V

Operating temperature

0 °C – 40 °C

Storage temperature

-20 °C – 50 °C

Protection rating

IP20

Dimensions


Base unit B x H x T

111 x 73 x 17 mm

Surface-mount frame B x H x T

180 x 108 x 27

stainless-steel front panel B x H x T

162 x 90 x 1,5

Operation


Voice communication

Integrated speaker
Integrated microphone

Controls

1 x alarm button (depending on version)

Indicators

2 x LED Pictogramm indicator
1 x Status-LED

Communication


Analog telephone interface FXO

Feed voltage 24–64 V DC
Feed current 20–50 mA
Ring signal 42–75 V / 20–50 Hz

Inputs and outputs


Filter-Input

ALARM voltage-free contact, NO/NC, for alarm button
INPUT voltage-free contact, NO
EOA voltage-free contact for end of alarm

Pictogram control

Output voltage = NRT supply voltage,
max. 100 mA per output

Key features


Call routing

to control centre with NRZ protocol
to control centre with P100 protocol
to telephone with voice message

Configuration

TERMINAL interface for PRG/PRK
Programming via telephone codes
Programming via control centre

Call destinations

4 telephone numbers for lift alarms
2 telephone numbers for notifications
1 telephone number for timer calls
Each number up to 25 digits

Level settings

Speaker volume adjustable in 20 steps
Microphone sensitivity adjustable in 20 steps

Voice messages

Identification message up to 20 seconds
Info message up to 10 seconds
Fault message up to 10 seconds

Firmware update

Via PRS/PRK